STEAM GENERATOR TUBES ZONES INSPECTED BY INTERCONTROLE AND ASSOCIATED TECHNIQUES

STEAM GENERATOR TUBES ZONES INSPECTED BY INTERCONTROLE AND ASSOCIATED TECHNIQUES

More than 5 million tubes inspected wordlwide

Technical Inspection

  • Bobbin coil for defect detection on full tube length
  • Rotating probe for higher sensitivity and defect characterization in specific areas with suspected degradations/flaws
  • Mix bobbin / phased-array probe to combine in one path defect detection on full tube length and characterization in specific areas with suspected degradations/flaws

METHODS

  • Multifrequency eddy currents
  • Analysis software AIDA
  • Helium leak detection

Inspection Reactor Steam Generator tube equipment

Manipulateur RANGER positionné sous la plaque à tube

RANGER manipulator positioned under the tubesheet

Tireur-pousseur et Générateur courants de Foucault

Eddy current instrument and probe pusher-puller 

Sondes à courant de Foucault

    Eddy current (ET) probes

Analyse de données sur base

Remote data analysis