STEAM GENERATOR TUBES ZONES INSPECTED BY INTERCONTROLE AND ASSOCIATED TECHNIQUES

More than 5 million tubes inspected wordlwide
Technical Inspection
- Bobbin coil for defect detection on full tube length
- Rotating probe for higher sensitivity and defect characterization in specific areas with suspected degradations/flaws
- Mix bobbin / phased-array probe to combine in one path defect detection on full tube length and characterization in specific areas with suspected degradations/flaws
METHODS
- Multifrequency eddy currents
- Analysis software AIDA
- Helium leak detection
Inspection Reactor Steam Generator tube equipment

RANGER manipulator positioned under the tubesheet

Eddy current instrument and probe pusher-puller

Eddy current (ET) probes

Remote data analysis